Everything below is a number you can check

Contract rates, the reactive rate card, the response matrix and the statutory calendar. Nothing here is “from”, nothing is “POA”, and nothing changes when you tell us the size of your estate.

Asset classes

What goes on the register

Every unit we maintain is tagged, photographed and entered with its make, model, serial, location, refrigerant type and charge in tonnes CO₂e — because the charge is what sets your legal leak-check interval, and most inherited registers do not record it.

Split and multi-split systems

Wall, cassette, ducted and floor-standing. Typically 1.5–14 kW, R32 or legacy R410A.

Planned interval
2 visits / year
Typical charge
1.2–7 t CO₂e

VRF and VRV

Outdoor modules, branch selectors and indoor fan coils on a shared circuit. Charge is per system, not per indoor unit.

Planned interval
2–4 visits / year
Typical charge
18–120 t CO₂e

Packaged chillers and dry air coolers

Air-cooled to 800 kW, glycol circuits, pumps and buffer vessels. Approach temperature and run hours trended visit to visit.

Planned interval
2–4 visits / year
Typical charge
60–500 t CO₂e

AHUs, HRV and extract

Belts, bearings, dampers, actuators and filters to ePM1 or ePM10 under ISO 16890 — the grades that replaced F7 and G4.

Planned interval
2–4 visits / year
Filter change
6–12 monthly

Kitchen extract and grease ductwork

Canopies, filters and the duct run itself, cleaned and certificated to BESA TR19 Grease with photographic evidence at each access point.

Clean interval
3–12 monthly by use
Signed off by
BESA GHT

Controls, BMS and switchgear

Trend, Tridium, BACnet and Modbus. Time schedules, setpoints, deadbands and sensor calibration — reviewed, not just backed up.

Planned interval
1–2 visits / year
Reported as
Setpoint audit

Contract tiers

Priced per asset, per year

Ex VAT, for a typical split within 45 minutes of Tyseley. Larger plant is quoted on survey against the same rate card. What separates the tiers is what the visit is allowed to consume — not how nice we are to you.

What is included

Compliance

£186per asset / yr

Planned

£348per asset / yr

Full cover

£595per asset / yr
Scheduled visits per year
1
2
4
F-Gas leak check at your statutory interval
Yes
Yes
Yes
Records lodged and certificate issued
Yes
Yes
Yes
Asset register and annual condition report
Yes
Yes
Yes
SFG20 planned task set per visit
—
Yes
Yes
Coil clean and condensate treatment
—
Annual
Twice
Filters and consumables
At cost
At cost
Included
Contracted P1 attendance
Next day
8 hrs
4 hrs
Reactive labour
Rate card
Rate card
Included
Parts to £250 per event
—
—
Included
Out-of-hours cover
—
Uplift
Included

Reactive rate card

What a breakdown costs if it is not included

Charged in 30-minute increments after the first hour. Travel inside the 90-minute radius is not charged to contract customers. These are the 2026–27 rates and they are the same rates that appear in the contract you sign.

Reactive labour and ancillary charges, 2026 to 2027
Charge Contract customer Non-contract Notes
Engineer, standard hours£68 / hr£86 / hrMon–Fri 08:00–17:00
Engineer, out of hours£92 / hr£124 / hr+35% · Mon–Fri 17:00–08:00
Engineer, weekend or bank holiday£102 / hr£138 / hr+50%
Second engineer, where access requires two£54 / hr£72 / hrRoof and confined-space work
Minimum attendance1 hr2 hrsIncludes diagnosis and report
Travel outside the 90-minute radius£0.62 / mile£0.62 / mileFrom Tyseley, one way
PartsCost + 12%Cost + 22%Invoice copy on request, always
Refrigerant, reclaimed R410AMarket + 10%Market + 20%Priced at the day's trade rate
TM44 inspection£340–£520£395–£580By accredited assessor, lodged

UK commercial HVAC day rates ran £350–£550 in 2026 and out-of-hours premiums 25–50%; ours sit inside both. We publish the comparison because a rate you cannot benchmark is not really a published rate.

The statutory calendar

What the law makes you do, and when

The intervals below are not our schedule — they are the statutory ones. Your contract is built around them so that compliance happens as a by-product of maintenance rather than as a panic in March.

5–50 t CO₂e

Leak check, 12-monthly

Most single splits and small VRF. Halved to 6-monthly only if the system has no fixed leak detection and sits at the top of the band.

50–500 t CO₂e

Leak check, 6-monthly

Larger VRF and most packaged chillers. Fixed leak detection halves the frequency again and usually pays for itself inside three years.

Over 500 t CO₂e

Leak check, quarterly

Industrial refrigeration and large chiller plant. Fixed detection is effectively mandatory at this scale.

Every 5 years

TM44 inspection

Any building with air conditioning rated 12 kW or more, including several small units that only add up to 12 kW. Report lodged on the national register.

F-Gas records must be kept five years and produced to the Environment Agency on request; civil penalties reach £200,000 per offence. A missing TM44 is £300, plus £200 for failing to produce the report within seven days of a request.

A basement plant room: large-bore pipework, valves and gearing in low light

The first visit

Half a day, and you own what comes out of it

The survey is free and it is not a sales call. We walk the plant with whoever holds the keys, tag every asset, photograph every nameplate, and read the charge off the plate rather than guessing it from the model number.

You get the asset register as a spreadsheet, the condition report as a PDF, and a costed list of anything we found that needs attention before a contract could sensibly start. All three are yours to keep and to show to whoever else you are asking. Four customers this year have used ours to renegotiate with their incumbent instead of switching, which is a fair outcome.

Book a site survey

Contract questions

The small print, in advance

How is an asset counted if one outdoor unit serves eight indoors?

As one system for refrigerant and leak checking, and as eight assets for the planned task set — because eight fan coils genuinely take eight times as long to filter and clean as one. The survey shows you exactly how your site is counted before you are asked to sign anything.

What is not covered at any tier?

Replacement plant, refrigerant beyond a top-up on a system with no active leak, damage from third parties or misuse, works arising from a design fault we did not create, and anything requiring scaffold or a mobile platform. Those are quoted separately, against the same rate card, and never started without a written order.

Do you subcontract?

Rarely, and never for anything under the F-Gas regime. Scaffold, specialist crane lifts and asbestos surveys go to named firms we have used for years, and they are disclosed on the quotation with their own accreditation numbers. Any subcontractor doing refrigerant work would have to hold their own company certificate — that is the law, not our policy.

Can we start mid-year?

Yes. The first invoice is pro-rated to the next quarter day and the statutory clock starts from your existing records, not from our arrival — so if your leak check is due in six weeks, it happens in six weeks.

Next step

Send us your last two invoices

If you already have a contract, that is the fastest way for us to tell you whether you are being fairly charged. We will say so if you are.